The API Downstream Segment has prepared thisstandard to cover large, field-assembled storage tanksof the type described in 1.2 that contain petroleumintermediates (gases or vapors) and finished products,as well as other liquid products commonly handled andstored by the various branches of the industry.

The rules presented in this standard cannot cover alldetails of design and construction because of thevariety of tank sizes and shapes that may beconstructed. Where complete rules for a specificdesign are not given, the intent is for theManufacturer–subject to the approval of thePurchaser’s authorized representative–to providedesign and construction details that are as safe asthose which would otherwise be provided by thisstandard.

Product Details

Edition:
11th
Published:
02/01/2008
Number of Pages:
254
File Size:
1 file , 3.4 MB
Redline File Size:
2 files , 11 MB
Product Code(s):
C62011R, C62011, C62011, C62011R, C62011R
Note:
This product is unavailable in Cuba, Iran, North Korea, Syria

API Std 620

Click here to purchase
API Standard 620 covers the design and construction of large, welded, field-erected low-pressure carbon steel aboveground storage tanks (including flat-bottom tanks) with a single vertical axis of revolution.

The rules presented in this standard cannot cover all details of design and construction because of the variety of tank sizes and shapes that may be constructed. Where complete rules for a specific design are not given, the intent is for the manufacturer-subject to the approval of the purchaser’s authorized representative-to provide design and construction details that are as safe as those which would otherwise be provided by this standard.

The tanks described in this standard are designed for metal temperatures not greater than 250 F and with pressures in their gas or vapor spaces not more than 15 pounds per square inch gauge.

The basic rules in this standard provide for installation in areas where the lowest recorded one-day mean atmospheric temperature is -50 F. Appendix R covers low-pressure storage tanks for refrigerated products at temperatures from +40 F to -60 F. Appendix Q covers low-pressure storage tanks for liquefied hydrocarbon gases at temperatures not lower than -270 F.

The rules in this standard are applicable to tanks that are intended to (a) hold or store liquids with gases or vapors above their surface or (b) hold or store gases or vapors alone. These rules do not apply to lift-type gas holders.

Although the rules in this standard do not cover horizontal tanks, they are not intended to preclude the application of appropriate portions to the design and construction of horizontal tanks designed in accordance with good engineering practice. The details for horizontal tanks not covered by these rules shall be equally as safe as the design and construction details provided for the tank shapes that are expressly covered in this standard.

Product Details

Edition:
10th
Published:
03/01/2002
Number of Pages:
196
File Size:
1 file , 1.9 MB
Product Code(s):
C62010, C62010, C62010
Note:
This product is unavailable in Cuba, Iran, North Korea, Syria

API Std 620

Click here to purchase
Best Available Copy

Product Details

Edition:
6th
Published:
07/15/1977
File Size:
1 file , 10 MB
Note:
This product is unavailable in Cuba, Iran, North Korea, Syria

API Std 620

Click here to purchase
Please note: as a requirement of the API committee that develops this publication, some addendums may not be available as standalone files, they are simply incorporated into the base publication.

The API Downstream Segment has prepared thisstandard to cover large, field-assembled storage tanksof the type described in 1.2 that contain petroleumintermediates (gases or vapors) and finished products,as well as other liquid products commonly handled andstored by the various branches of the industry.

The rules presented in this standard cannot cover alldetails of design and construction because of thevariety of tank sizes and shapes that may beconstructed. Where complete rules for a specificdesign are not given, the intent is for theManufacturer–subject to the approval of thePurchaser’s authorized representative–to providedesign and construction details that are as safe asthose which would otherwise be provided by thisstandard.

Product Details

Edition:
12th
Published:
10/01/2013
Number of Pages:
277
File Size:
1 file , 3.4 MB
Redline File Size:
2 files , 16 MB
Product Code(s):
C62012-CN2740, C62012, C62012-CN2740, C62012, C62012-CN2740, C62012
Note:
This product is unavailable in Cuba, Iran, North Korea, Syria

API Std 620

Click here to purchase
Best Available Copy

Product Details

Edition:
7th
Published:
09/01/1982
Number of Pages:
178
File Size:
1 file , 11 MB
Note:
This product is unavailable in Cuba, Iran, North Korea, Syria

API Std 620

Click here to purchase
Best Available Copy

Product Details

Edition:
8th
Published:
06/01/1990
Number of Pages:
184
File Size:
1 file , 12 MB
Note:
This product is unavailable in Cuba, Iran, North Korea, Syria